home button icon
 
Heading Text: Office Equipment, Field Hardware
Air Pipe Manifolds


Flow Finder Manifold
6-port Flow Finder Manifold As the first air pipe manifold designed as a serious leak locating tool, the System Studies Flow Finder Manifold™ offers unparalleled ease and accuracy in air flow measurement. What makes our manifolds uniquely different from old style manifolds are their built-in Flow Finders™. Each chamber in the manifold is equipped with a Flow Finder to measure the outgoing flow to an individual cable. Another Flow Finder, of a higher flow range, measures incoming flow from the air pipe.

Flow Finder Manifolds are available in two models, P/N 9800-3060 and P/N 9800-3070. Both of these models provide air distribution to a maximum of five cables (via five outgoing ports, each containing a Flow Finder). In addition to its five outgoing ports, the 9800-3060 Flow Finder Manifold is equipped with an incoming port to measure the total flow into the manifold.

Unlike the 3060 manifold, the 3070 model is not a stand-alone manifold; it is designed to be used together with the 3060 to provide air delivery at locations with more than five cables.


Ordering Information

PART NUMBER RANGE* FITTINGS**
9800-3060 SIX PORT
(1 incoming, five outgoing to cables)
L, M, H, C BS, BV, SS, SV, BT
9800-3070 FIVE PORT
(Used with 9800-3060 to feed 10 cables)
L, H, C
(Designates output range)
BS, BV, SS, SV, BT

*Range:
Low: Input = 19.0 SCFH, Output = 9.5 SCFH
Medium: Input = 47.5 SCFH, Output = 9.5 SCFH
High: Input = 95 SCFH, Output = 195 SCFH
Custom: Multiple output ranges to meet customer specifications (contact System Studies
Incorporated)
**Fittings:
BS  Manifold(s) supplied with nickel-plated brass, standard tubing connectors. For use with
3/8" plastic tubing.
BV  Manifold(s) supplied with nickel-plated brass, standard tubing connectors, along with
nickel-plated brass check valves on all outputs. For use with 3/8" plastic tubing.
SS  Manifold(s) supplied with stainless steel 37° flared tubing connectors. For use with 1/4"
stainless steel braided tubing.
SV  Manifold(s) supplied with stainless steel 37° flared tubing connectors, along with nickel-
plated brass check valves on all outputs. For use with 1/4" stainless steel braided tubing.
BT  Manifold(s) supplied with nickel-plated brass tubing connectors. For use with 1/2" plastic
tubing.

Ordering Examples:
If you ordered Part Number 9800-3070-H-SV, for example, you would receive a five port flow Finder Manifold with a high flow range (0–19 SCFH flow anges at each of manifold outports) and 37° stainless steel tubing connectors with nickel-plated brass check valves. This model is not intended to be used as a stand-alone manifold; it is designed to be used with the 9800-3060 Flow Finder Manifold.

A 9800-3060-L-BS is a six port Flow Finder Manifold equipped with a 0–19 SCFH Flow Finder measuring incoming flow and 0–9.5 SCFH Flow Finders for each of the outports. Five nickel-plated brass tubing connectors are supplied for each of the manifold's outports, and one nickel-plated brass, 45° street elbow with a 1/4" NPT thread is supplied to accommodate input from the air pipe.

Note: Please refer to our product data sheet for additional information about the Flow Finder Manifolds. Pricing information can be obtained from your Purchasing Department or by calling System Studies Incorporated at 800-247-8255.